SA-103 FEATURES
ERROR DETECTION
The Plinius SA-103 Power Amplifier has in-built error detection. This will function under the following
conditions:
When the amplifier is overdriven/clipped
If any internal fuse is damaged
Should either of these circumstances arise the amplifier will disconnect both channels and mute the input.
This condition will remain until the input signal level is reduced or the damaged fuse replaced. When
error detection is triggered the power LED will turn off and the mute LED will pulse. The internal error
LED (located towards the front of the circuit board in the top cavity of the amplifier) will also light.
FUSE PROTECTION
When any internal fuse is damaged one or more fuse warning LEDs will light. These LEDs are under the
amplifier lid located near the centre of the main circuit board with the rail fuse holders. If any of the
internal fuse LED’s are glowing, the lid of the amplifier will need to be removed and the fuse adjacent to
the lit LED should be replaced. Replace them with the same type (10 amp normal blow).
IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.
Please note that fuse failure may indicate a severe problem. Check all speakers and speaker cables for
damage/short circuit etc. Should the amplifier continue to exhibit rail fuse failure contact your PLINIUS
dealer.
ECOLOGIC CONTROL
The Plinius SA-103 is also fitted with a microprocessor which monitors and performs the Bias and Mute
functions. It is programmed to switch the amplifier back into Class AB if no signal has been present at the
input for a predetermined time. This time can be adjusted to Off, 15, 30 or 60 minutes. During the last
minute without signal the bias LED will pulse to indicate the unit is about to return to Class AB. The
purpose of this function is to prevent the amplifier being left in Class A while unattended for a long period
of time.
To adjust this time constant the amplifier lid must be removed and the small jumper JP4 located on the
main circuit board at the front left shifted to the appropriately labelled pins. Please ensure that your
amplifier is switched OFF and disconnected from the mains supply before this adjustment is made. The
factory setting is 30 minutes.